Mounting Dosing pump Dosi-Pump
Fixing the pump to the container
Before purchasing please consider:
The Dosing pump is mounted by you on your existing container closure. Take the diameter of the drillhole from the table.
Description |
Drillhole Ø | Item number |
---|---|---|
Dosing pump Dosi-Pump 4 ml |
21 mm | 5607-1004 |
Dosing pump Dosi-Pump 30 ml |
28,5 mm |
5607-2030 |
Dosing pump Dosi-Pump 30 ml, fixed feeding tube |
22 mm | 5607-3030 |
Dosing pump Dosi-Pump 100 ml, fixed feeding tube |
28,5 mm | 5607-4100 |
Dosing pump Dosi-Pump 250 ml, fixed feeding tube |
28,5 mm | 5607-5250 |
The "Dosing pump Dosi-Pump 4 ml" (5607-1004) can also be mounted without drilling.
The "Dosing pump Dosi-Pump 100 ml, fixed feeding tube" (5607-4100) and "Dosing pump Dosi-Pump 250 ml, fixed feeding tube" (5607-5250) can no longer be dismantled after mounting.
Mounting
1. Drilling drillhole
Drill the drillinghole in the container closure on which you want to mount the Pump.
(Drillhole's diameter see the table above.
2. Loosing threaded nut
Screw threaded nut counterclockwise to loose it from the Dosi-Pump.
3. Inserting pump through
Insert the Dosi-Pump from above through the drillinghole of the container closure.
4. Fixing Dosi-Pump
Fix the Dosi-Pump from below with the threaded nut on the container closure.
5. Attaching container closure
Attach the container closure to the container. The Dosi-Pump is ready for use.